Linear Mode

PLASMA-ARC-THROUGH

STERILIZE PIG MANURE, SLUDGE OR LEACHATES -RECYCLERS WHILE PRODUCING SYNGAS FUEL

PROCESS MAIN FUNCTIONS:

  1. Sterilization of highly contaminated biowastes without chemical additives
  2. Partial abatement of BDOD and pre-treatment of contaminants;
  3. Production of SynGas to use as fuel and production of heat.

TREATMENT

For the case of pig manure; SynGas Biowaste Refinery can be used in three main modes for the purpose of producing:

  1. Organic solid fertilizer, SynGas fuel, and depurated irrigation water;
  2. Organic solid fertilizer, SynGas fuel and waters for municipal discharges;
  3. Organic liquid fertilizers, SynGas fuel and 1% solids for municipal discharges. For the case of municipal or industrial sludge or landfill leachates, Plasma-Arc-Through reactors achieve complete sterilization and partial treatment of contaminants conventional equipments can be used for the treatment of downstream effluents, according to the needs of the clients and local regulatory requirements.

PRODUCTION

The volume of bioliquids processed per hour depends on power, Total Suspended Solids (TSS) chemical contaminants and other factors. Magnegas production also varies depending on TSS as weil as organic content. As an illustration, the 300 kW Plasma-Arc-Through Recycling Plant depicted below can process pig manure with 1% TSS at the rate of about 30,000 gallons or about 135,000 Liters per eight hour working day while producing about 16,000 scf or about 500 m3 df Magnegas Fuel also per eight hours day.

SAMPLE PROCESSING OF INDUSTRIAL SLUDGE DONE BY 200KW PAT RECYCLER AT CIS CONSORTION IN BENEVENTO, ITALY

 

ETICHETA DEL CAMPIONE COD MG02/L BODS5 MG02/L NITRATES MG/L AMMONIA PPM E. COLI UFC/100ML COLIFORM TOTAL UFC/100ML TOTAL BACTERIALOGICAL COUNT
RAW LIQUID 80,000 32,000 346.5 6 Off Count Off Count Off Count
AFTER PAT MODUAL 2,000 800 390.06 5.8 Absent Absent Absent
AFTER SAND  FILTER 230 92 356.59 5.4 Absent Absent Absent
AFTER CHARCOLE ACTIVATED FILTER 120 48 172.71 5.4 Absent Absent Absent
AFTER UV STATION 90 36 244.98 5.5 Absent Absent Absent

Example equipment in USA

 

 

All rights reserved 2017 Planet One Solutions